Onv-XP UPS
Online UPS 100-1000kVA
High Reliability
- Built-in LP inductor for motor loads.
- Wide input voltage range of -60% to +25%, showcasing remarkable adaptability to various grid conditions.
- Strong Overload Capacity: Handles overloads effectively for stable performance.
- Seamless Maintenance: Hot-swappable design ensures uninterrupted operation during maintenance.
- Dual Redundant Control: Dual cards and DSP controls prevent single failure point.
- Efficient Fan Control: Intelligent fan management and redundancy save energy, sustaining 25% load with 2 fans failed and 50% with 1 fan failed.
- Comprehensive Protection: Integrated input, output, bypass breaker, and manual bypass enhance system safety.
- Emergency Power-Off (EPO): Standard EPO function swiftly disconnects power during emergencies.
- Durable PCBs: Anti-corrosion coating on all PCBs boosts longevity.
Green Power
- Achieves up to 97% AC/AC efficiency, even at 30% load, minimizing heat and saving power costs.
- ECO mode offers up to 99% efficiency, reducing expenses. W-ECO mode reaches 98.5% efficiency, lowering TCO with fast transfers.
- High input power factor (up to 0.99) and low Input THDi (< 3.0% at full load) cut grid pollution and costs.
- Advanced and compact 3U height 100KW power module equipped with maximum 30A charger.
- Enable self-loading test functionality for convenient debugging and on-site testing prior to real load connection. This eliminates the need for expensive temporary loads, cabling, and breakers, resulting in energy and cost savings.
Industrial
Robots
Factory Automation
Distribution Centers
Elevators
Machinery
Hot-Swap
LP Inductor
Graphic Touch Screen
Advanced technology
- Three level technology ensures low harmonics, remarkable efficiency, and substantial energy conservation.
- The Power Walk-in feature mitigates inrush current to the main power source or generator.
- Advanced parallel expansion technology supports 8 units up to 9.6MW in parallel, single /parallel system compatible.
- Self-dedusting function which saves the service time.
- The Parallel ECO mode maximizes overall system efficiency during parallel operation.
- Common battery bank on parallel mode.
- Frequency converter function (60Hz to 50Hz or 50Hz to 60Hz)
User-friendly Interface
- User-friendly ON/OFF – Double physical button design to avoid false operation.
- Equipped with a 7-inch touch screen with LED Indicators, ensuring comprehensive and visualized information display.
- Large data storage capacity,10000 entry events logs.
- User-Friendly Interface – A friendly human-machine interface presenting data and graphical representations.
- Hassle-free software updates on-site, enabling a singular update for all power and control modules.
- ON/OFF – Double Button design to prevent maloperations and touch screen failure.
- Smart programmable dry contact communication function.
Intelligent Management
- Fault Trace Management (FTM) for convenient failure analysis (waveform record before & after of the fault point for 200ms) which easily figure out faulty point.
- Battery Life Extension: Use a three-stage charging system to prolong battery lifespan.
- Intelligent Battery Management: Replace faulty batteries (30-50 per string) instead of the entire set.
- Early Warning System: Get alerted about potential faults with pre-alarm on key parts.
- Efficient Asset Tracking: Keep track of part replacements, timelines, and service details for effective management.
Options
Battery Monitoring Solutions:
- Advanced battery monitoring per block voltage, Impedance, and temperature.
Flexible Network Management:
- Optional internal SNMP adapter
- Customer interface software
Intelligent management software:
- Smart status diagnosis
- Abnormal status real time alarm
- Event logs recording
- Parameters real time monitoring
More Options
- Bypass voltage regulator
- Extended dry contact card
- BMS card for lithium battery
- Input and output isolation transformer
- Output Synchronization Common Bus
- Battery Charge Temperature Compensation
TECNED Onv-xp Specifications 100-300 kVA
| MODEL | ONV-XP 100 | ONV-XP 150 | ONV-XP 200 | ONV-XP 250 | ONV-XP 300 | |
| Power module Model | XPD-50 | XPD-100 | ||||
| Voltage Range (Vac) | 3Φ4W+PE, 380/400/415, L-L: 138~485 | |||||
| Input Wiring | 3Ph+N+PE | |||||
| Input Frequency (Hz) | 40-70 | |||||
| Bypass Voltage Range (Vac) | -20% (10/15/30/40/50/60%) ~ +15% (10/20/25%) | |||||
| Power Factor | ≥0.99 | |||||
| THDi at full Linear load | <3% | |||||
| Output | ||||||
| Power Module (kW) | 50kW | 100kW | ||||
| Power Module Number | 2+1 | 3+1 | 4+1 | 5+1 | 3+1 | |
| System Capacity (kVA) | 100 | 150 | 200 | 250 | 300 | |
| Power Factor | 1 | |||||
| Voltage (Vac) | 3Φ4W+PE, L-L: 380,400,415 ±1% | |||||
| Frequency (Hz) | 50/60 ±0.2% (battery mode) | |||||
| Three Phase Difference | True sine wave,≤2 degrees | |||||
| THDv | ≤1% (linear load, full load); ≤4% (no linear load, full load) | |||||
| Static Bypass Transfer Time | 0 | |||||
| System Efficiency (MAX) | 97% | |||||
| Overload Capacity | 101-105% Long run, 106-110% load for 60 minutes, 111%-125% load for 10 minutes, 126%-150% load for 1 minute, over 150% load transfer to bypass | |||||
| Battery | ||||||
| Battery Voltage (Vdc)* | ±240 (±180~±300 settable) | |||||
| Charging Current (A) | N×30 Maximum (N = the number of power module) | |||||
| Others | ||||||
| Display | 7-inch Touch screen+ LED+ Physical buttons | |||||
| Operating Temperature (ºC) | 0~40 | |||||
| Storage Temperature (ºC) | -40~70 | |||||
| Relative Humidity | 0~95%, no condensation | |||||
| Communication Function | RS232, RS485, Dry contact, MODBUS, SNMP (optional) | |||||
| Noise (dB) | 70 | |||||
| Altitude (m) | 0~2000, no derating | |||||
| Cabling | Bottom/Top | |||||
| Power Module Dimension (mm) W×D×H | 500×750×130(3U) | |||||
| Cabinet Dimension (mm) W×D×H | W:600 D:860 H:2000 | W:1200 D:1000 H:2000 | ||||
| Weight (kg) | Cabinet | 228 | 240 | 291 | ||
| Power Module | 33 | 55 | ||||
TECNED Onv-xp Specifications 400-1000 kVA
| MODEL | ONV-XP 400 | ONV-XP 500 | ONV-XP 600 | ONV-XP 800 | ONV-XP 1000 | |
| Power module Model | XPD-100 | |||||
| Voltage Range (Vac) | 3Φ4W+PE, 380/400/415, L-L: 138~485 | |||||
| Input Wiring | 3Ph+N+PE | |||||
| Input Frequency (Hz) | 40-70 | |||||
| Bypass Voltage Range (Vac) | -20% (10/15/30/40/50/60%) ~ +15% (10/20/25%) | |||||
| Power Factor | ≥0.99 | |||||
| THDi at full Linear load | <3% | |||||
| Output | ||||||
| Power Module (kW) | 100kW | |||||
| Power Module Number | 4+1 | 5+1 | 6+1 | 8+1 | 10+2 | |
| System Capacity (kVA) | 400 | 500 | 600 | 800 | 1000 | |
| Power Factor | 1 | |||||
| Voltage (Vac) | 3Φ4W+PE, L-L: 380,400,415 ±1% | |||||
| Frequency (Hz) | 50/60± 0.2% (battery mode) | |||||
| Three Phase Difference | True sine wave,≤2 degrees | |||||
| THDv | ≤1% (linear load, full load); ≤4% (no linear load, full load) | |||||
| Static Bypass Transfer Time | 0 | |||||
| System Efficiency (MAX) | 97% | |||||
| Overload Capacity | 101-105% Long run, 106-110% load for 60 minutes, 111%-125% load for 10 minutes, 126%-150% load for 1 minute, over 150% load transfer to bypass | |||||
| Battery | ||||||
| Battery Voltage (Vdc)* | ±240 (±180~±300 settable) | |||||
| Charging Current (A) | N×30 Maximum (N = the number of power module) | |||||
| Others | ||||||
| Display | 7-inch Touch screen+ LED+ Physical buttons | |||||
| Operating Temperature (ºC) | 0~40 | |||||
| Storage Temperature (ºC) | -40~70 | |||||
| Relative Humidity | 0~95%, no condensation | |||||
| Communication Function | RS232, RS485, Dry contact, MODBUS, SNMP (optional) | |||||
| Noise (dB) | 70 | |||||
| Altitude (m) | 0~2000, no derating | |||||
| Cabling | Bottom/Top | |||||
| Power Module Dimension (mm) W×D×H | 500×750×130(3U) | |||||
| Cabinet Dimension (mm) W×D×H | W:800 D:1000 H:2000 | W:1400 D:1000 H:2000 | W:1800 D:1000 H:2000 | |||
| Weight (kg) | Cabinet | 325 | 580 | 650 | 745 | |
| Power Module | 55 | |||||